Wet Bulb Temperature and Dew Point Temperature to Relative Humidity Converter

Enter the known properties and either total pressure or height above sea level to calculate relative humidity.

Calculator inputs

Air pressure input

Extract the full archive before opening the calculator so its scripts can load.

Relative Humidity

— %

Calculation history

No calculations saved on this page yet.

    Input calculation

    Obtain the moisture term from the first reading, then calculate the dry bulb temperature from the second property.

    Pv = Psat(Tdp)
    W = 0.622 × Pv / (P − Pv)
    Tdb = [h(Twb, Ws) − (Ws − W) hf(Twb) − 2500 W] / (1.005 + 1.88 W)

    Formula for relative humidity

    Water vapour partial pressure expressed as a percentage of saturation pressure at the dry bulb temperature.

    RH = 100 × Pv / Psat(Tdb)

    Symbols

    Tdb
    Dry bulb temperature (DB), in °C.
    Twb
    Wet bulb temperature (WB), in °C.
    Tdp
    Dew point temperature (DP), in °C.
    W
    Intermediate water-vapour mass per kilogram of dry air, obtained from q/(1 − q) when known.
    Ws
    Saturated value of W at the indicated temperature.
    RH
    Relative humidity, in percent.
    h
    Moist-air enthalpy (ET), in kJ/kg dry air.
    hf
    Enthalpy of liquid water or ice at the wet bulb temperature relative to liquid water at 0 °C, in kJ/kg water.
    Pv
    Water vapour partial pressure (PV), in kPa.
    Psat
    Saturation vapour pressure at the temperature in parentheses, in kPa.
    P
    Total atmospheric pressure (PT), in kPa.

    Quantity definitions and calculation range

    Worked example

    Wet Bulb Temperature 18.724547 °C · Dew Point Temperature 14.196543 °C · height 0 m

    Relative Humidity = 45.39 %

    More calculations with these inputs

    Wet Bulb Temperature and Dew Point Temperature to All Properties